Case
Studies
GRL Engineers offer a wide range of deep foundation testing and consulting services, nationwide. Most GRL Engineers have achieved Advanced Level or higher on both the PDCA/PDI Dynamic Measurement and Analysis Proficiency Test.

Featured
Pensacola Bay Bridge
The U.S. 98 Pensacola Bay Bridge replacement project began in 2017 to address hurricane evacuation traffic needs. The replacement required PDA Testing on test piles and production piles. Data was assessed via CAPWAP® data analyses to provide simulated static load testing. Hurricane Sally interrupted construction in 2019, and potential damages to production piles were assessed using Low Strain Integrity Testing. Read more
Featured
Toombs County Bridge Replacement over the Altamaha River
GRL performed Drilled Shaft Verticality Assessment, Shaft Base Cleanliness Assessment, as well as Bi-Directional Static Load Testing (“BDSLT”) services. A multi-level jack assembly configuration increased the complexity of shaft installation requirements, load test execution, and test data analyses. Thermal Integrity Profiling was also utilized during concrete curing to measure thermal data every 15 minutes. Read more
Featured
I-77 Canton Bridge Structures
The large aquifer in Canton, OH presented multiple drilled shaft installation challenges on the I-77 mainline bridge structures. GRL Engineers were involved in mulitple phases of construction, providing a variety of testing services including Dynamic Load Testing with an APPLE drop weight system, CAPWAP® Analyses to simulate static load testing, Drilled Shaft Base Cleanliness Evaluations, Thermal Integrity Profiling, and Static Load Testing on CFA piles. The project was considered monumental as it was the Ohio DOT's first time utilizing Dynamic Load Testing on a CFA pile. Read more

Tri-State Tollway Mile-Long Bridge
In 2020, GRL Engineers were contracted to perform testing on the Mile-Long Bridge located in Willow Springs, Illinois. Various testing methods were performed to assess the concrete integrity including Crosshole Sonic Logging, Thermal Integrity Profiling, and Data Analyses.

North Madison Substation
GRL Engineers took on an investigative project on the North Madison Substation in Wisconsin, to analyze acceleration and stresses in non-uniform piles during vibratory driving. The test involved Dynamic Pile Monitoring using a Pile Driving Analyzer (PDA) and the PDI-VIB Program.

1100 Broadway Avenue in Oakland
GRL Engineers were contracted to perform Dynamic Pile Monitoring with a Pile Driving Analyzer (PDA) and collect high-strain dynamic measurements using APPLE Load Testing. A CAPWAP Analysis was performed using the collected test data.

Milwaukee 7Seventy7 Apartments

Harbor River Bridge

New Jersey Floodwall

Cairo Bridge over the Fork Hughes River

SR-19 Over Little Lake Harris Bridge

Russell Street Bridge

Norfolk Southern Railroad

Tappan Zee Bridge

Corpus Christi Export Terminal

Veterans Memorial Bridge

Washington Port of Tacoma

Bonner Bridge

Kentucky Lake Bridge

SR 36 Bridge over Tuscarawas River